SunMaxx Solar Installs Solar Thermal System at the Army Reserve Center in Winder, Georgia

The project was conducted in conjunction with Pond & Company, who supplied the architectural and engineering services as well as McLeroy Plumbing who installed the systems at the Army Reserve Center in Winder, GA. The new solar thermal heating systems will do their part to meet the Army’s goal of moving away from fossil fuels, while providing the most up to date training facility. The first solar thermal installation included 40 TitanPowerPlus SU2 series flat plate collectors and an 806 gallon non-pressurized solar storage tank for domestic hot water. A second system was installed for the OMS building, which included […]

SunMaxx Solar Announces Solar Thermal Storage Tank Manufacturing Facility in Binghamton , NY

FOR IMMEDIATE RELEASE –March 15, 2012 – Binghamton , NY – SunMaxx Solar, a leading, vertically integrated manufacturer of solar thermal systems and components, is pleased to announce that the company now manufactures non-pressure storage tanks out of their Binghamton, New York facility . SunMaxx manufactures a variety of solar hot water storage tanks designed for commercial and government installations. Combining both European and U.S. technology, the new tanks store large amounts of solar energy at lower temperatures, which will reduce costs and improve quality and overall performance of the solar systems. The non pressure storage tanks are the perfect […]

SunMaxx Solar Collectors Installed at First Solar Powered Brewery in New Hampshire

New London, NH March 10, 2011 SunMaxx Solar is proud to announce the successful installation of twenty-five SunMaxx TitanPower Plus-SU2 solar flat plate collectors at the Flying Goose Brew and Pub as it becomes the first solar powered brewery in New Hampshire. In an ongoing effort to become a more energy efficient business, Flying Goose recently upgraded to a solar thermal system which uses a non-pressurized 806 gallon tank to preheat water for the restaurant and brew cycles. Installed by the SunMaxx authorized installer Clean Resolutions, the system consists of 500 square feet of SunMaxx TitanPower Plus-SU2 flat plates, which […]

How do I properly size my storage tank for the collector area?

The rule of thumb of 1-3 gallons of storage per ft2 of collector will only get you so far, so it is best to try being creative with your storage. As your load increases in the winter and production decreases, you should adjust your storage capacity accordingly. Even slight changes from day to day in your production vs. consumption, can dramatically affect total system performance. Tank prioritization allows you to maintain a target temperature in one tank while still charging another. Better yet, you may be able to run directly from your solar field to your heat load and bypass […]

How do I know which type of storage tank that I need?

Well, there are really two main options here; pressurized tank or non-pressure tank. The pressure tank will come with heat exchange coils on the inside (2 or 3 depending on style) that will be tied into a closed solar loop and open DHW loop. The additional coil (s) can be used for space heating or auxiliary heating. The drwaback to large pressurized tanks is that they require larger doors when you exceed 200 gallons or so. The Non-pressure tanks are basically custom built, insulated tubs that can be brought in through the smallest of doors and assembled on location to a volume […]

How do I know which size of storage tank I need?

There are many answers to this question but it really boils down to this…you need the one that best suits your application, your solar collector field, your budget and your available space. If you use a Heliomaxx kits from Sunmaxx, we have sized the storage vessels relative to the size of the collector field. For sizing, we generally consider first the temperature requirement of the tank. For instance, if you need your solar tank to be a cetain temperature before it ties into your home heating sytem then we would likely reduce the storage capacity but if you are using […]

How do I determine the most appropriate solar thermal storage size?

Q: How to determine the best solar thermal storage size. A: Choosing your storage tank size is dependent on three things. 1- the number of ft2 of collector- for example we typically recommend any where from 1-3 gallons of storage per ft2 of collector,   2- the daily load profile (usage pattern) for example if most of your usage occurs in the early morning or in the evening, then you would not adjust your storage ratio. However, if your usage occurs more in the mid-day then you would reduce your storage ratio because you will be consuming that which you […]

Example Dialog Text







Expected Timeline to purchase?:

Customer Type:

 

Please help us fight spam! What is the sum of 7 + 4?

 
Contact SunMaxx Solar SunMaxx Solar
Sales & Main Office
Rte 206
Bainbridge, NY 13733

P: 1.877.SUNMAXX
P: 1.877.786.6299
www.SunMaxxSolar.com