TitanPower Flat Plate Collectors

To check the temperature sensor you can use the digital multimeter tool and check the resistance of the sensor.A simple steps which allow to check the temperature sensor:
  1. Turn the system off (electricity) - safety us the most important
  2. Open the controller box
  3. Check if the connection is not loose
    • If loose fix the connection by pushing the sensor wire inside the terminal
    • Close the controller box and check if that fixed the issue
  4. Check the sensor wire resistance with multimeter (turn the multimeter switch to the resistance measurement) – reading should be around 1.101 kOhm at room temperature and around 1.250 kOhm for hot water
    • If readings are different sensor might need replacement
This short advice should help you to solve the problem.