There can be a lot of reasons which lead to problems with sensor reading error. Due to this you can follow the steps below, maybe they can help you to solve the problem:Remember to turn of the appliance form electricity, safety is the most important
  1. Check all wires - connection is required to correct work of sensor. If there is a loose, try to put in harder inside
    1. If problem vanish, your repair is completed
    2. If no follow the next step
  2. Take the multimeter tool and check the current flow of the wire. If you have some values, the sensor is fully functional
  3. When you still have a problem you can constant to engineering team, maybe they can help you or replace the whole device.
These simply step can help to solve the problem.  
To check the temperature sensor you can use the digital multimeter tool and check the resistance of the sensor.A simple steps which allow to check the temperature sensor:
  1. Turn the system off (electricity) - safety us the most important
  2. Open the controller box
  3. Check if the connection is not loose
    • If loose fix the connection by pushing the sensor wire inside the terminal
    • Close the controller box and check if that fixed the issue
  4. Check the sensor wire resistance with multimeter (turn the multimeter switch to the resistance measurement) – reading should be around 1.101 kOhm at room temperature and around 1.250 kOhm for hot water
    • If readings are different sensor might need replacement
This short advice should help you to solve the problem.