503469

What type of splice should I use when joining sensor cables to system wiring?

What type of splice should I use when joining sensor cables to system wiring? Do not use wire nuts or connectors. Solder all wire connections, and cover them with shrink wrap tubing. Additionally, since most shrink wrap tubing is not rated as high temp or UV resistant, make sure that those...

Read more...

My sensor cable is only 4 feet long. How do I wire it from the controller all the way to the collectors?

My sensor cable is only 4 feet long. How do I wire it from the controller all the way to the collectors? First off, when wiring to the collectors, make sure you use the high temp sensor (usually black or red). One end of the sensor cable has the sensor, which...

Read more...

Setting your solar thermal system differential temperature setpoint.

Q:What is the most appropriate differential temperature for my solar thermal system? A: The factory setting on our controllers is 12 Degrees. This will work fine but for northern climates it is better to have a delta T of 17 Degrees. This will allow the collector to heat up sufficiently so...